Skip Ribbon Commands
Skip to main content
Sign In

22608 Immune Complexes, C1q Binding (096933)

Immune Complexes, C1q Binding  (096933)
Test Code: MISC
Synonyms/Keywords
​CIC, C1q Binding, C1q Binding Test, C1q Immune Complexes, Circulating Immune Complexes, Complement C1q Immune Complexes, Immune Complex Detection by C1q
Useful For
Monitor immune complex disease (ie, lupus, glomerulonephritis, serum hepatitis, arthritis, vasculitis); monitor progress of some malignancies
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Serum​ ​Red Top Tube (RTT) ​Serum Separator Tube (SST) ​1 mL ​0.1 mL
Collection Processing Instructions
Separate serum from cells within 30 minutes of collection and freeze serum in plastic tube immediately.​
Specimen Stability Information
Specimen Type Temperature Time
​Serum ​ Samples may be stored at 2°C to 8°C prior to testing.​ ​7 days
Frozen >7 days​
Rejection Criteria
Hemolysis Reject
Heating specimen for thawing may give false-positive results​ Reject​
Avoid repeated thawing and freezing.​
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
LabCorp of America​ Performed Tuesday and Thursday​ 1 day Enzyme immunoassay (EIA)​
Reference Lab
Reference Range Information
Performing Location Reference Range
LabCorp of America​

Negative: <4.4 μg Eq/mL

Equivocal: 4.4-10.7 μg Eq/mL

Positive: >10.7 μg Eq/mL

Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​86332
Synonyms/Keywords
​CIC, C1q Binding, C1q Binding Test, C1q Immune Complexes, Circulating Immune Complexes, Complement C1q Immune Complexes, Immune Complex Detection by C1q
Ordering Applications
Ordering Application Description
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Serum​ ​Red Top Tube (RTT) ​Serum Separator Tube (SST) ​1 mL ​0.1 mL
Collection Processing
Separate serum from cells within 30 minutes of collection and freeze serum in plastic tube immediately.​
Specimen Stability Information
Specimen Type Temperature Time
​Serum ​ Samples may be stored at 2°C to 8°C prior to testing.​ ​7 days
Frozen >7 days​
Rejection Criteria
Hemolysis Reject
Heating specimen for thawing may give false-positive results​ Reject​
Avoid repeated thawing and freezing.​
Useful For
Monitor immune complex disease (ie, lupus, glomerulonephritis, serum hepatitis, arthritis, vasculitis); monitor progress of some malignancies
Reference Range Information
Performing Location Reference Range
LabCorp of America​

Negative: <4.4 μg Eq/mL

Equivocal: 4.4-10.7 μg Eq/mL

Positive: >10.7 μg Eq/mL

For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
LabCorp of America​ Performed Tuesday and Thursday​ 1 day Enzyme immunoassay (EIA)​
Reference Lab
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​86332