Skip Ribbon Commands
Skip to main content
Sign In

22610 Immune Complexes, Raji Cell (096156)

Immune Complexes, Raji Cell (096156)
Test Code: MISC
Synonyms/Keywords
​CIC by Raji Cell, Raji Cell Assay,  Complement c3d, Complement c3dg, Complement ic3b, Immune Complex Assay by Raji Cell
Useful For
​Detect circulating immune complexes (CIC) containing C3 activation fragments, such as ic3b, c3d,g, and c3d.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Serum​ ​Red Top Tube (RTT) ​Serum Separator Tube (SST) ​1 mL ​0.1 mL
​Plasma ​EDTA Lavendar Top Tube (LTT) ​1 mL ​0.1 mL
Collection Processing Instructions
Transfer specimen to a plastic transport tube before freezing. Freeze at -70°C or store on dry ice within six hours of collection. Storage of specimens at -20°C will yield erroneous results. ​
Specimen Stability Information
Specimen Type Temperature
​Serum or Plasma Freeze at -70°C​
Rejection Criteria
Specimen not shipped frozen Reject
Storage of specimens at -20°C will yield erroneous results.​
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
LabCorp of America​ Performed Tuesday and Thursday ​1day Enzyme immunoassay (EIA)​
Reference Lab
Reference Range Information
Performing Location Reference Range
LabCorp of America​

Normal: ≤15.0 μg Eq/mL

Equivocal: 15.1-19.9 μg Eq/mL

Positive: ≥20.0 μg Eq/mL​

Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​86332
Synonyms/Keywords
​CIC by Raji Cell, Raji Cell Assay,  Complement c3d, Complement c3dg, Complement ic3b, Immune Complex Assay by Raji Cell
Ordering Applications
Ordering Application Description
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
Serum​ ​Red Top Tube (RTT) ​Serum Separator Tube (SST) ​1 mL ​0.1 mL
​Plasma ​EDTA Lavendar Top Tube (LTT) ​1 mL ​0.1 mL
Collection Processing
Transfer specimen to a plastic transport tube before freezing. Freeze at -70°C or store on dry ice within six hours of collection. Storage of specimens at -20°C will yield erroneous results. ​
Specimen Stability Information
Specimen Type Temperature
​Serum or Plasma Freeze at -70°C​
Rejection Criteria
Specimen not shipped frozen Reject
Storage of specimens at -20°C will yield erroneous results.​
Useful For
​Detect circulating immune complexes (CIC) containing C3 activation fragments, such as ic3b, c3d,g, and c3d.
Reference Range Information
Performing Location Reference Range
LabCorp of America​

Normal: ≤15.0 μg Eq/mL

Equivocal: 15.1-19.9 μg Eq/mL

Positive: ≥20.0 μg Eq/mL​

For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
LabCorp of America​ Performed Tuesday and Thursday ​1day Enzyme immunoassay (EIA)​
Reference Lab
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​86332