22933 Transfusion Reaction Workup

Transfusion Reaction Workup
Test Code:  
Synonyms/Keywords
TRANSFUSION REACTION​
Test Components
ABO/RH, DAT​
Useful For
Investigation of a transfusion reaction.​
Specimen Requirements
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No​ Whole blood​ 6 mL EDTA
Pink Top Tube
(PTT)​
Two 3 mL EDTA Lavender Top Tubes (LTT)​ 3 mL ​ 2.5 mL ​ Two 0.5 mL microcollection tubes​
Collection Processing Instructions
A sample must be collected immediately after transfusion reaction is reported to Transfusion Service department.​
Specimen Stability Information
Specimen Type Temperature Time
Whole blood​ Refrigerate​ STAT collection​
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield​ Monday through Sunday​ Less than 2 hours​ Serological/Clerical​
Test Information
Notify the Transfusion Service IMMEDIATELY after a transfusion reaction or suspected transfusion reaction occurs. Transfusion Service personnel will perform the required laboratory tests.
Nurse is required to complete the Investigation of Reported Transfusion Reaction form #25081519​
Reference Range Information
Performing Location Reference Range
Marshfield​ No reference ranges are available​
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
86880 ​
Synonyms/Keywords
TRANSFUSION REACTION​
Test Components
ABO/RH, DAT​
Ordering Applications
Ordering Application Description
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Fasting Required Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
No​ Whole blood​ 6 mL EDTA
Pink Top Tube
(PTT)​
Two 3 mL EDTA Lavender Top Tubes (LTT)​ 3 mL ​ 2.5 mL ​ Two 0.5 mL microcollection tubes​
Collection Processing
A sample must be collected immediately after transfusion reaction is reported to Transfusion Service department.​
Specimen Stability Information
Specimen Type Temperature Time
Whole blood​ Refrigerate​ STAT collection​
Useful For
Investigation of a transfusion reaction.​
Test Components
ABO/RH, DAT​
Reference Range Information
Performing Location Reference Range
Marshfield​ No reference ranges are available​
For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
Marshfield​ Monday through Sunday​ Less than 2 hours​ Serological/Clerical​
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
86880 ​