Skip Ribbon Commands
Skip to main content
Sign In

25649 PD-L1, SP142 FDA (TECENTRIQ/atezolizumab) IHC

PD-L1, SP142 FDA (TECENTRIQ/atezolizumab) IHC 
Test Code: MISCTIS
Synonyms/Keywords
PD-L1, PDL1, SP142, TECENTRIQ, ATEZOLIAUMAB, IHC, Immunohistochemistry
Test Components
PD-L1 Immunohistochemistry (IHC) SP142 Ventana Kit, using a rabbit monoclonal antibody, clone SP142, incorporating an OptiView DAB IHC detection and amplification system.
Useful For
Qualitative/semi-quantitative measurement of PDL1 on tumor cells of urothelial carcinoma and non-small cell lung cancer (NSCLC). This clone was used in OAK and POPLAR clinical trials with FDA approval for urothelial cancer and lung cancer.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
​Tissue ​FFPE Block One (1) unbaked, unstained slide cut at 4-5 microns for H&E staining (required) and two to three (2-3) positively charged unstained slides cut at 3-4 microns for each test/antibody ordered ​Must have atleast 1000 tumor cells
Collection Processing Instructions
Use cold pack for transport. Make sure cold pack is not in direct contact with specimen.
Specimen Stability Information
Specimen Type Temperature
​FFPE ​Ship with cold pack
Rejection Criteria
Less than 100 tumor cells
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
​NeoGenomics Laboratories ​Monday through Saturday

​48 hours

Turnaround time (Analytical time + 2 days): 4 days
TAT for late pending functionality ONLY
Immunohistochemistry (IHC)/ VENTANA BenchMark ULTRA
Reference Lab
Reference Range Information
See Report
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​88360
Synonyms/Keywords
PD-L1, PDL1, SP142, TECENTRIQ, ATEZOLIAUMAB, IHC, Immunohistochemistry
Test Components
PD-L1 Immunohistochemistry (IHC) SP142 Ventana Kit, using a rabbit monoclonal antibody, clone SP142, incorporating an OptiView DAB IHC detection and amplification system.
Ordering Applications
Ordering Application Description
If the ordering application you are looking for is not listed, contact your local laboratory for assistance.
Specimen Requirements
Specimen Type Preferred Container/Tube Acceptable Container/Tube Specimen Volume Specimen Minimum Volume
(allows for 1 repeat)
Pediatric Minimum Volume
(no repeat)
​Tissue ​FFPE Block One (1) unbaked, unstained slide cut at 4-5 microns for H&E staining (required) and two to three (2-3) positively charged unstained slides cut at 3-4 microns for each test/antibody ordered ​Must have atleast 1000 tumor cells
Collection Processing
Use cold pack for transport. Make sure cold pack is not in direct contact with specimen.
Specimen Stability Information
Specimen Type Temperature
​FFPE ​Ship with cold pack
Rejection Criteria
Less than 100 tumor cells
Useful For
Qualitative/semi-quantitative measurement of PDL1 on tumor cells of urothelial carcinoma and non-small cell lung cancer (NSCLC). This clone was used in OAK and POPLAR clinical trials with FDA approval for urothelial cancer and lung cancer.
Test Components
PD-L1 Immunohistochemistry (IHC) SP142 Ventana Kit, using a rabbit monoclonal antibody, clone SP142, incorporating an OptiView DAB IHC detection and amplification system.
Reference Range Information
See Report
For more information visit:
Performing Laboratory Information
Performing Location Day(s) Test Performed Analytical Time Methodology/Instrumentation
​NeoGenomics Laboratories ​Monday through Saturday

​48 hours

Turnaround time (Analytical time + 2 days): 4 days
TAT for late pending functionality ONLY
Immunohistochemistry (IHC)/ VENTANA BenchMark ULTRA
Reference Lab
For billing questions, see Contacts
Outreach CPTs
CPT Modifier
(if needed)
Quantity Description Comments
​88360
For most current information refer to the Marshfield Laboratory online reference manual.